OUR BIO MEDICAL WASTE TREATMENT MACHINE ECODAS T150

OUR WASTE TREATMENT MACHINE ECODAS T150

SUMMARY

Our patented process is designed to shred and sterilize infectious waste to reduce its volume, and render its components unrecognizable all in one fully enclosed and automated, stainless steel, system.

It combines shredding, direct steam and high pressure to treat infectious materials.

The contaminated waste is loaded into the upper chamber where a heavy-duty, high-torque, low speed shredder reduces the waste into small pieces.

Using gravity, the processed material drop into the lower treatment chamber, where every particle is steam heated to 138°C (280 F) and pressurized to 3,5 bar (51 psi) for 10 minutes. The operating and treatment conditions are continuously monitored and validated to achieve complete sterilization (Microbial inactivation = 108).

After the cooling process, the final product is volume-reduced (by up to 80 %), rendered unrecognizable and safe to recycle or to dispose as ordinary municipal waste.

The 30 minutes duration of an average cycle process is fully automated and totally monitored.  A computerized control system scans the process and automatically prints a batch report at the end of each cycle with the essential sterilizing parameters for accurate record keeping.


DATA SHEETS

telecharger_fiche_technique_EN

GENERAL CHARACTERISTICS

 
Dimensions ( L x l x H )
Dimensions ( L x W x H )
274x200x300 CM
6.9 x 7.2 x 9 F.T
Shipping Weight800 KG
Max weight when filled with water For a special hydraulic test1100 KG
Stress1 KG/CM2
Steam Pressure8 BARS
Max Steam Flow65 KG/H
Compressed Air6 BARS
Electricity 380V / Three phase8 KW

OPERATING CHARACTERISTICS

 
Average Cycle Time30 MIN
Process Volume Capacity150 LITERS
Average Waste Density100 - 150 KG/M3
Average Process Weight Capacity15-23 KG/CYCLE
33-51 LB/CYCLE
Microbial Inactivation108
Waste Volume Reduction80%

CONSUMPTION / CYCLE

 
STEAM9 KG
ELECTRICITY1.4 KWH
WATER15 LITERS

 


1. Loading
2. Shredding
3. Heating
4. Sterilization
5. Cooling
6. Draining
7. & 8. Unloading

CASE STUDY

Site dimensions20 M²
Average Cycle Time Load to Load 30 MIN
Volume Capacity150 LITERS / 39.6 GAL
Average Process Weight Capacity15 – 25 KG/CYCLE
33 – 55 LB/CYCLE
Number of ShiftsAverage Annual Machine Capacity
1Shift – 40 hrs/wk79 T
174,116 LB
2Shifts – 80 hrs/wk158 T
348,232 LB
3Shifts – 120hrs/wk237 T
522,348 LB


REFERENCES

Algeria, Azerbaijan, Bulgaria, Cameroon, Canada, Egypt, France, Gabon, Ghana, India, Iran, Iraq, Jordan, Kurdistan, Kuwait, Libya, Palestine, Panama, Russia, Saint Pierre & Miquelon, Senegal, Sudan, Syria, Turkey, Vietnam.

MORE


CERTIFICATIONS / APPROVALS

ECODAS The process has been tested by the Institut Pasteur de Lille, and approved by the Superior Council of Public Hygiene of France ( CSHPF ), under the Ministry of Health and the Ministry of the Environment (click to view document): 

T150 Homologation : Juillet 9th 2008

The quality management of ECODAS systems is executed following ISO 9001

ECODAS Systems are designed and manufactured in accordance with the following norms (click to view document):

American : ASME (the American Society Mechanical Engineers)

Chinese : MLSE

European : CE

Japanese : MHLW

Russian : GOSSTANDART