OUR HOSPITAL WASTE TREATMENT MACHINE ECODAS T100

OUR WASTE TREATMENT MACHINE ECODAS T100

SUMMARY

Our patented process is designed to shred and sterilize infectious waste to reduce its volume, and render its components unrecognizable all in one fully enclosed and automated, stainless steel, system.

It combines shredding, direct steam and high pressure to treat infectious materials.

The contaminated waste is loaded into the upper chamber where a heavy-duty, high-torque, low speed shredder reduces the waste into small pieces.

Using gravity, the processed material drop into the lower treatment chamber, where every particle is steam heated to 138°C (280 F) and pressurized to 3,5 bar (51 psi) for 10 minutes. The operating and treatment conditions are continuously monitored and validated to achieve complete sterilization (Microbial inactivation = 108).

After the cooling process, the final product is volume-reduced (by up to 80 %), rendered unrecognizable and safe to recycle or to dispose as ordinary municipal waste.

The 30 minutes duration of an average cycle process is fully automated and totally monitored.  A computerized control system scans the process and automatically prints a batch report at the end of each cycle with the essential sterilizing parameters for accurate record keeping.


 

DATA SHEETS

telecharger_fiche_technique_EN

GENERAL CHARACTERISTICS

 
Dimensions (L x W x H)
Dimensions (L x W x H)
200x120x212 CM
6.6x3.8x7 F.T
Shipping Weight635 KG
Max weight when filled with water For a special hydraulic test780 KG
Stress0.1 KG/CM2
Steam Pressure8 BARS
Max Steam Flow35 KG/H
Compressed air6 BARS
Electricity 380V / Three phase5 KW

OPERATING CHARACTERISTICS

 
Average Cycle Time30 MIN
Process Volume Capacity
100 LITERS
Average Waste Density100 - 150 KG/M3
Average Process Weight Capacity10-15 KG/CYCLE
22-33 LB/CYCLE
Microbial Inactivation108
Waste Volume Reduction80%

CONSUMPTION / CYCLE

 
STEAM6 KG
ELECTRICITY0.55 KWH
WATER5 LITERS


 

1. Loading
2. Shredding
3. Heating
4. Sterilization
5. Cooling
6. Draining
7. & 8. Unloading

CASE STUDY

Site Dimensions6 M²
Average Cycle Time Load to Load 30 MIN
Volume Capacity100 LITERS / 26.4 GAL
Average Process Weight Capacity10 – 15 KG/CYCLE
22 – 33 LB/CYCLE
Number of ShiftsAverage Annual Machine Capacity
1Shift – 40 hrs/wk52 T
114,608 LB
2Shifts – 80 hrs/wk104 T
229,216 LB
3Shifts – 120hrs/wk156 T
343,824 LB


EXAMPLE OF ACHIEVEMENTS

REFERENCES

Algeria, Bangladesh, Estonia, Ghana, Iran, Iraq, Jordan, Mauritania

MORE


CERTIFICATIONS / APPROVALS

ECODAS The process has been tested by the Institut Pasteur de Lille, and approved by the Superior Council of Public Hygiene of France ( CSHPF ), under the Ministry of Health and the Ministry of the Environment (click to view document): 

T100 Homologation : March 1st 2013

The quality management of ECODAS systems is executed following ISO 9001

ECODAS Systems are designed and manufactured in accordance with the following norms (click to view document):

American : ASME (the American Society Mechanical Engineers)

Chinese : MLSE

European : CE

Japanese : MHLW

Russian : GOSSTANDART